Rise Garden 3: DC40 Water Pump Guide
October 30 2024 9:39pm • Est. Read Time: 2 MINRise Garden 3 Water Pump
Your Rise Garden 3 water pump operates 24/7, connected to its power supply. Equipped with a filter, an outlet tube with a coupler, that connects to the supply tube for steady water flow.
Care & Maintenance
For optimal performance and longevity, it's essential to clean your water pump every six months, along with your Deep Clean. Follow these maintenance steps:
Tools Needed:
Screwdriver
Sponge
Vinegar Based-Cleaner (EXAMPLE)
Cleaning Steps:
Disassemble: Remove the four screws holding the pump cover in place. (For a step-by-step video on how to disassemble the water pump: DC40 HERE).
Rotator Removal: Carefully pull out the pump's rotator.
Cleaning: Make 50/50 vinegar and warm water solution. Use a sponge and solution to scrub away any buildup on the rotator, inside of the pump, and pump cover. Pay close attention to the inside of the pump connector, removing any debris you find.
To ensure we properly address all issues, we strongly suggest that you clean your supply line and filters. After cleaning the pump's interior, rotor, and cover, ensure they are thoroughly clean. Refer to the image below for a visual guide.
Troubleshooting
Issue 1: Pump Does Not Start
Over time, debris can accumulate within the pump, reducing water flow. If your pump has stopped working, cleaning it is often the solution. Before cleaning, please ensure the following:
If these steps don't resolve the issue, refer to our pump cleaning guide above.
Issue 2: Pump Starts and Stops
If your pump is noisy or has reduced flow, trapped air or debris might be the issue. This can occur during installation, rapid water addition, if the pump runs dry, or nutrient buildup.
Steps:
Unplug: Disconnect the pump from the power source.
Remove Filter: Take out the pump filter.
Submerge and Tilt: Keeping the pump submerged, tilt it so the intake is facing upwards.
Toggle On: Without reattaching the filter, turn on the pump using the button.
Swish and Release: Swish the pump around in the water to dislodge any bubbles. Allow the water to flow back into the tank, releasing any trapped air.
Reinstall Filter: Once the air is released, reattach the pump filter.
Reconnect Power: Plug the pump back into the power source.
Pump with incline upwards (DC40)
Issue 3: Pump Is Noisy
A noisy water pump can be caused by wear and tear and the pump's vibration, to address this, see below:
Pump Wear and Tear: Over time, pump components can wear down, leading to increased noise. Cleaning the pump with a white vinegar solution can help restore its performance. Please refer to our pump cleaning guide above.
Pump Vibration: If the pump is vibrating against the reservoir, it can amplify the noise. To mitigate this, try repositioning the pump assembly within the reservoir. Experiment with different placements to find the quietest spot.